How To Solution Error Code: 2000, 2010, Kyocera 3010i/3011i || Kyocera TASKalfa error C2000

Аватар автора
Умный дом: технологии комфорта
Kyocera TASKalfa error C2000 Kyocera TASKalfa error C2010 Code: 2000 Main motor steady-state error. Stable OFF is detected for 1 s continuously after main motor stabilized Causes, Defective connector cable or poor contact in the connector. Defective drive transmission system of the main motor. Defective main motor. Defective engine PWB. Remedy, Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Main motor and engine PWB (YC16) Defective drive transmission system of the main motor. Check if the rollers and gears rotate smoothly. If not, grease the bushes and gears Check for broken gears and replace if any. Defective main motor. Replace the main motor. Defective engine PWB. Replace the engine PWB and check for correct operation. Code: 2010 Main motor drive error. The main motor is not stabilized within 2s after driving starts. Causes, Defective connector cable or poor contact in the connector. Defective drive transmission system of the main motor. Defective main motor. Defective engine PWB. Remedy, Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Main motor and engine PWB (YC16) Defective drive transmission system of the main motor. Check if the rollers and gears rotate smoothly. If not, grease the bushes and gears. Check for broken...