Cypcut Alarm: Local Capacity Small | BCS100 Setting | Fiber Laser

Аватар автора
Сила ума и разума
The video tells the cypcut alarm of fiber laser: local capacity small, it replates the BSC100 setting, basic steps are displayed in it. When we meet the “Local Capacity Small” alarm, first we need to figure out it happened while the machine is in processing or resting condition. If the alarm occurs at “Stop” state, we need to touch the bottom nozzle by hand or other tools. And at the same time, checking whether the value C in Height Controller is changed to 0. If it is 0 when we touch the nozzle, please go to the Height Controller. Press F1 and then 2, we will get into the calibration interface. Then we need to let the cutting head jogging close to the metal sheet and do the Capacitance Calibration. If the alarm is still there after the Capacitance Calibration, we should press F2 and then 7, get into Alarm Settings. Check whether the parameters here are set properly. We can appropriately adjust the alarm value of “Local Capacity Small”. Note that the number in front of + is not recommended to be greater than 1000. If it is not 0 when we touch the nozzle, we need to take the ceramic ring down from the cutting head. And find the thimble, touch it by hand or some other tools. At the same time, we also need to see whether the C value in Height Controller is changed to 0. If it is 0 when we touch the thimble of ceramic ring, we can tell it is the problem, we should replace the ceramic ring. If it isn’t 0 when we touch the RF wire thimble, the wire is damaged and we should...