How to Fusing reset error code H2-00 H Sharp MX-M265NE MX-M264N M314N M354N #sharp #subscribe

Аватар автора
Технотека
troubleshoot section Reset error code: H2-00, H2-01, H3-00, H3-01, H4-00, H4-01, H5-01. ★ Code: H2-00 Thermistor open trouble (TH_UM) Main thermistor open hardware detection. Main thermistor trouble PCU PWB trouble. Thermistor connector and harness connection trouble Fusing section connector connection trouble Fusing unit not installed Remedy Use SIM44-14 to check the state of the thermistor. Replace the thermistor. Replace the PCU PWB. Check connection of the thermistor connector and the harness. Check the connector in the fusing section. ★ ★ ★ ★ ★ ★ ★ Code: H2-01 Thermistor open trouble (TH_US) Sub thermistor open hardware detection trouble. Sub thermistor trouble PCU PWB trouble.Thermistor connector and harness connection trouble Fusing section connector connection trouble Fusing unit not installed. Remedy, Use SIM44-14 to check the state of the thermistor. Replace the thermistor. Replace the PCU PWB. Check connection of the thermistor connector and the harness. Check the connector in the fusing section. ★ ★ ★ ★ ★ ★ ★ Code: H3-00 Fusing section high temperature trouble (TH_UM) Main heater lamp abnormally high temperature software detection trouble. Causes, The fusing temperature exceeds the specified level. Main thermistor trouble PCU PWB trouble. Thermistor connector and harness connection trouble Power unit trouble. Remedy, Use SIM44-14 to check the state of the thermistor. Use SIM5-2 to check the flashing operation of the...